Digital Screen Colors and Physical Swatch Fidelity
The swatch textures, photographic previews, and finish samples depicted across this website (including Solid Colors, Metallic Series, Timber Wooden ACP, and Stone Textures) are rendered electronically for general aesthetic visualization only.
Structural Engineering & Subframe Responsibility
InfySheets functions solely as a manufacturer and distributor of aluminium composite panels. InfySheets does not provide structural facade engineering design, civil certification, or subframe stress calculations.
- The Purchaser, lead architect, or designated facade consultant is solely responsible for determining the suitable sheet thickness (3mm, 4mm, or 6mm), aluminium skin gauge (0.25mm vs 0.50mm), and alloy grade according to specific coastal wind load pressures, building heights, and seismic zones in accordance with IS 875 (Part 3).
- Selection and structural adequacy of aluminium/galvanized steel subframe runners, bracket spacing, anchor bolts, expansion joints, and weather-resistant structural silicone sealants must be validated by certified civil or facade engineers.
Fire Safety Regulations & Building Heights
Building fire safety codes vary across jurisdictions and building occupancies (such as commercial high-rises, hospitals, educational institutions, and residential towers):
- Standard LDPE Core Panels: Polyethylene core ACP is intended primarily for low-rise facades (typically below 15 meters), retail canopy cladding, and non-critical signage applications as permitted by regional building bylaws.
- FR Grade Mineral Core Panels: For high-rise commercial facades, institutions, and public assembly buildings, the Purchaser must mandate InfySheets FR Grade (Class A / Class B certified to ASTM E84 / EN 13501-1) in compliance with the National Building Code of India 2016 (Part 4 Fire and Life Safety).
- InfySheets disclaims any liability arising from the deployment of non-FR panels in locations where local municipal bylaws or fire department clearances mandate non-combustible materials.
Estimations and Cut-Sheet Feasibility
Any surface area calculations, sheet optimization layouts, or cut-sheet advice rendered by our Coastal Project Desk or depot personnel are provided purely as goodwill technical assistance. Certified fabricators must physically verify site envelope dimensions, elevation offsets, and bending allowances before cutting or grooving panels.
Cleaning Agents and Surface Protection
InfySheets PVDF finishes are engineered to resist saline coastal air, moisture, and UV rays. However, exposure to harsh acidic chemicals, abrasive powders, strong solvents, or industrial wash chemicals will void the coating warranty. Cleaning must be carried out using clean water and neutral PH mild detergents with soft sponges.
Request Technical Datasheets
For verified lab test reports, ASTM certificates, or specific alloy datasheets, connect directly with our engineering assistance team:
InfySheets Technical Support Bureau
InfySheets, NH 66, Kota, Udupi, Karnataka - 576221
Direct Inquiries: contact@infysheets.com
Phone / WhatsApp: +91 99023 44835